NEW QUESTION 13
An engineer is troubleshooting a failed DCBX exchange between a server and a Cisco Nexus switch. Which action allows DCBX to successfully negotiate?

  • A. Enable LLDP.
  • B. Enable Cisco Discovery Protocol.
  • C. Enable ETS
  • D. Enable PFC.

Answer: A

 

NEW QUESTION 14

Refer to the exhibit. An engineer is configuring boot from iSCSI on a Cisco UCS B-Series Blade Server, but the LUN fails to mount. Which action resolves the issue?

  • A. Statically configure the target information in the Boot Policy.
  • B. Configure an MTU size of 9000 on the appliance port.
  • C. Configure a QoS policy on the vNIC.
  • D. Set a connection timeout value of 250 in the iSCSI Adapter Policy.

Answer: A

Explanation:
Section: Compute Platforms

 

NEW QUESTION 15
Refer to the exhibit.

An engineer is configuring boot from iSCSI on a Cisco UCS B-Series Blade Server, but the LUN fails to mount. Which action resolves the issue?

  • A. Statically configure the target information in the Boot Policy.
  • B. Configure an MTU size of 9000 on the appliance port.
  • C. Configure a QoS policy on the vNIC.
  • D. Set a connection timeout value of 250 in the iSCSI Adapter Policy.

Answer: A

 

NEW QUESTION 16
A Fibre Channel interface on a Cisco Nexus 5000 Series Switch receives bit errors, and the switch disables the interface. A temporary workaround must be implemented before the root cause is identified. Which action prevents this issue from reoccurring?

  • A. Verify that the SFPs are supported.
  • B. Run the shutdown and then no shutdown commands on the interface.
  • C. Run the switchport ignore bit-errors command on the interface.
  • D. Change the SFP to operate at 4 Gbps instead of 2 Gbps.

Answer: C

Explanation:
Section: Storage Network

 

NEW QUESTION 17
DRAG DROP
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.
Select and Place:

Answer:

Explanation:

Section: Compute Platforms

 

NEW QUESTION 18
A customer reports that the Chassis Management Controller fails to receive chassis information from Cisco UCS Manager. Which set of steps resolves the issue?

  • A. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.
  • B. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.
  • C. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.
  • D. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.

Answer: C

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ts/guide/UCSTroubleshooting/UCSTroubleshooti

 

NEW QUESTION 19
An engineer is troubleshooting a fabric discovery failure. Which two requirements must an engineer verify about switch connectivity to solve the problem? (Choose two.)

  • A. Leaf nodes must connect to spine nodes only.
  • B. A Cisco APIC must be attached to leaf nodes.
  • C. A Cisco APIC must be dual-attached to two separate spine nodes.
  • D. A Cisco APIC must be attached to a spine node only.
  • E. Spine nodes must connect to other spine nodes.

Answer: A,B

Explanation:
Section: Network

 

NEW QUESTION 20
Refer to the exhibit.

The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?

  • A. Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.
  • B. Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric.
  • C. Reactivate the zoneset.
  • D. Reconfigure the initiator and the target to be in the same zones.

Answer: C

 

NEW QUESTION 21
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all options are used.

Answer:

Explanation:

 

NEW QUESTION 22

Refer to the exhibit. After the configuration is performed, guestshell continues to use 2%CPU. Which action resolves the issue?

  • A. Reboot the switch
  • B. Resync the database
  • C. Recreate the guestshell
  • D. Reboot the guestshell

Answer: D

Explanation:
Section: Automation

 

NEW QUESTION 23

Refer to the exhibit. The vPC between switch1 and switch2 does not work. Which two actions resolve the problem? (Choose two.)

  • A. Match the vPC domain ID between the two devices.
  • B. Configure one of the switches as primary for the vPC.
  • C. Activate VLANs on the vPC.
  • D. Configure the IP address on the interface.
  • E. Correct the configuration of the vPC peer link and the vPC peer keepalive.

Answer: A,C

Explanation:
Section: Network

 

NEW QUESTION 24
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.

Answer:

Explanation:

 

NEW QUESTION 25
Refer to the exhibit.

The HSRP configuration in the exhibit fails to function. Which action resolves this issue?

  • A. Configure the same HSRP group on both devices.
  • B. Configure HSRP version 2.
  • C. Enable IP redirects.
  • D. Set the MTU to 1500 bytes.

Answer: C

 

NEW QUESTION 26

Refer to the exhibit. The EEM script overrides all events in the system policy. What should be added to the script to resolve the issue?

  • A. environment variable
  • B. event-default action statement
  • C. configure terminal action
  • D. event statement

Answer: D

Explanation:
Section: Automation

 

NEW QUESTION 27
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.

Answer:

Explanation:

 

NEW QUESTION 28
A customer configures HSRP between two data centers that are interconnected with OTV. The configuration succeeds, but traffic between two ESXi virtual hosts on the same site is routed suboptimally through the OTV overlay. Which two actions optimize the traffic? (Choose two.)

  • A. Filter HSRP by using a Layer 2 MAC-list on the ESXi vSwitch.
  • B. Filter HSRP traffic by using a Layer 3 VACL on the ESXi vSwitch.
  • C. Filter HSRP by using a Layer 2 MAC-list on the OTV edge devices.
  • D. Filter HSRP traffic by using a Layer 3 VACL on the OTV edge devices.
  • E. Disable first-hop redundancy.

Answer: D,E

 

NEW QUESTION 29
Refer to the exhibits.



An engineer troubleshoots switch N5K1, which fails to receive traffic from the file server Which set of actions resolves this problem?

  • A. Assign native VLAN 10 with fc2.'l - 2 and allow VLAN 10 in trunk configuration.
  • B. Assign native VLAN 10 with vfc111 and allow VLAN 1101 in trunk configuration.
  • C. Bind native VLAN 10 with Ethemet1/10 and allow VSAN 101 in trunk configuration.
  • D. Bind native VLAN 10 with Ethemet10/1/1 and allow VLAN 10 in trunk configuration

Answer: D

 

NEW QUESTION 30
Refer to the exhibits.



An engineer troubleshoots switch N5K1, which fails to receive traffic from the file server Which set of actions resolves this problem?

  • A. Bind native VLAN 10 with Ethemet10/1/1 and allow VLAN 10 in trunk configuration
  • B. Assign native VLAN 10 with fc2.'l - 2 and allow VLAN 10 in trunk configuration.
  • C. Assign native VLAN 10 with vfc111 and allow VLAN 1101 in trunk configuration.
  • D. Bind native VLAN 10 with Ethemet1/10 and allow VSAN 101 in trunk configuration.

Answer: D

 

NEW QUESTION 31
Refer to the exhibit.

An engineer must connect N2K-Fex-1 and N5K-Core-1 so that the traffic flow between the two devices uses load balancing. After inspecting the statistics of the interconnecting interfaces, the engineer concludes that only one link is used. Which action resolves the problem?

  • A. Configure each uplink to be a member of a separate LACP port channel.
  • B. Configure the pinning max-link as 2.
  • C. Configure destination-mac load balancing on N5K-Core-1
  • D. Configure source-destination load balancing on N5K-Core-1.

Answer: B

Explanation:
Explanation
https://www.cisco.com/c/m/en_us/techdoc/dc/reference/cli/n5k/commands/pinning-max-links.html

 

NEW QUESTION 32
Refer to the exhibit.

The connection between a Cisco Nexus 5548UP switch and a Cisco MDS switch fails to initialize. What is the cause of the issue?

  • A. Trunk mode must be activated.
  • B. The SFP is unsupported.
  • C. The interface is in an incorrect mode.
  • D. VSAN 1 is suspended.

Answer: A

 

NEW QUESTION 33

Refer to the exhibit. A PC belongs to VLAN 68. The user experiences a large amount of packet loss when communicating with hosts that are outside of VLAN 68. Which action resolves the problem?

  • A. Remove the HSRP configuration.
  • B. Replace HSRP with GLBP.
  • C. Enable the peer-gateway feature.
  • D. Configure ip arp synchronization on both switches.

Answer: C

Explanation:
Section: Network
Explanation
Explanation/Reference: https://community.cisco.com/t5/networking-documents/peer-gateway-feature-on-the-nexus-7000/ ta-p/3113290

 

NEW QUESTION 34
An engineer must upgrade all components in a Cisco UCS domain to the same package version, but the upgrade process fails to complete. Which set of Auto Install actions resolves the problem?

  • A. Install Infrastructure Firmware, then Install Server Firmware.
  • B. Install Hypervisor Firmware, then Install Infrastructure Firmware
  • C. Install infrastructure Firmware, then Install Hypervisor Firmware.
  • D. Install Server Firmware, then Install Infrastructure Firmware

Answer: A

Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-5/b_GUI_Firmware_Management_25/b_GUI_Firmware_Management_25_chapter_0111.pdf

 

NEW QUESTION 35
An engineer discovers that an NPV/NPIV uplink experiences a heavy load and plans to add more uplinks. Which statement about what occurs when the new uplinks are added is true?

  • A. Paths must be defined before new connections can use the new uplinks.
  • B. New and existing connections use the new uplinks automatically.
  • C. Only new connections use the new uplinks automatically.
  • D. All connections must be reset before the new uplinks can be used.

Answer: B

 

NEW QUESTION 36
Refer to the exhibit.

An engineer troubleshoots the HSRP configuration and notes that the remote end uses HSRP version 1. The engineer sets the local HSRP to version 1, but the problem continues. Which action resolves the issue?

  • A. Change the local group number to 255 or less and request that the remote data center matches the group member in its configuration.
  • B. Reduce the priority of the local HSRP to below 100 to force the local HSRP to standby and then change the version to version 1.
  • C. Run version 1 and version 2 HSRP on VLAN300 in the local data center.
  • D. Set the local group number as 300 in the remote data center configuration

Answer: A

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/ios-xml/ios/ipapp_fhrp/configuration/xe-16/fhp-xe-16-book/fhp-hsrp-v2.p

 

NEW QUESTION 37
Refer to the exhibit.

Partial configuration from N9K-1 and N9K-2 is included. The client has two WANs connected.
* WAN-1 is for normal business-day activities.
* WAN-2 is for server backups during nonworking hours of 1:00 a.m. to 5:00 a.m. daily.
The client says that at the scheduled time for backup, the data center server failed to use the WAN-2 link to back up the servers to the cloud backup system. What is the solution to this problem?

  • A. The event timer must be written in epoch time format.
  • B. The applet called "Backup" must include an action to remove the current static route.
  • C. The Cron entry must be configured without double quotes.
  • D. The Cisco Nexus switch must be configured with one applet because a configuration with two applets will fail.

Answer: B

 

NEW QUESTION 38
......