Cisco and NetApp FlexPod NS0-176 Dumps Updated Jan 15, 2022 - TrainingQuiz [Q64-Q87]

Share

Cisco and NetApp FlexPod NS0-176 Dumps | Updated  Jan 15, 2022 - TrainingQuiz

Master 2022 Latest The Questions Cisco and NetApp FlexPod and Pass NS0-176  Real Exam!

NEW QUESTION 64
Your company is looking for a small remote office infrastructure to deploy to your 30 remote sites. You are asked to write deployment procedures for each site. Your goal is to have each site deployed in less than a day.
Which tool will help you accomplish your goal?

  • A. UCS Manager
  • B. OnCommand Insight
  • C. OnCommand System Manager
  • D. UCS Director

Answer: D

 

NEW QUESTION 65
Exhibit:

You just configured a new Storage Virtual Machine named SVM1 on your NetApp cluster to serve up NFS datastores to an ESX cluster.
Your VMware administrator tells you that the ESX servers are unable to access the datastore that you created on node flexpod1-san01-01. The IP address of one of the ESX servers is 10.33.128.100.
Referring to the exhibit, which command would you use to troubleshoot this problem?

  • A. ~network ping -lif cluster mgmt -vserver flexpodl-san01 - destination 10.33.128.100~
  • B. ~network ping -lif flexpod1-san01-01 mgmt1 -vserver flexpod1-san01 -destination 10.33.128.100~
  • C. ~network ping -node flexpod1-san01-01 -destination 10.33.128.100~
  • D. ~network ping -lif nfs1 -vserver svm1 -destination 10.33.128.100~

Answer: D

 

NEW QUESTION 66
How many cluster interconnect switch(es) are required for a 4-node NetApp cluster?

  • A. 0
  • B. 1
  • C. 2
  • D. 3
  • E. 4

Answer: E

 

NEW QUESTION 67
A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC.
When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown.
What caused this issue?

  • A. The Nexus switches do not have NPV enabled.
  • B. The Nexus must be configured for FCoE instead of native Fibre Channel.
  • C. The Nexus switches do not have NPIV enabled.
  • D. The zoning on the Nexus switches is incorrect.

Answer: C

 

NEW QUESTION 68
You are asked to verify your MPIO settings for your ONTAP FlexPod solution. You are using VMware ESXi 6 and FCP as the storage protocol.
In this scenario, which MPIO setting would you use on the ESXi host?

  • A. most recently used
  • B. round robin
  • C. fixed path
  • D. fixed path with array preference

Answer: B

 

NEW QUESTION 69
Which three management tools would you use to configure the NetApp storage component in a FlexPod Datacenter solution? (Choose three.)

  • A. Cisco UCS Director
  • B. Cisco UCS Central
  • C. NetApp OnCommand Perfromance Manager
  • D. NetApp Virtual Storage Console (VSC) for VMware Sphere
  • E. NetApp OnCommand System Manager

Answer: B,D,E

 

NEW QUESTION 70
Which pool of addresses is created under Servers tab in UCS Manager as part of the Service Profile creation process?

  • A. UUID Suffix Pools
  • B. WWNN Pools
  • C. WWPN Pools
  • D. MAC Pools

Answer: A

 

NEW QUESTION 71
An administrator is trying to present an NFS datastore to an ESXi host.
Which two must be available before mounting? (Choose two.)

  • A. junction path case sensitivity
  • B. host name case sensitivity
  • C. export policy access
  • D. datastore name case sensitivity

Answer: B,C

 

NEW QUESTION 72
You are asked to create an interface group on a NetApp clustered Data ONTAP system. The system is connected to a Cisco Nexus switch in a vPC configuration with the port-channel mode set to active.
Which NetApp interface group made matches this switch configuration?

  • A. mode active
  • B. singlemode
  • C. multimode
  • D. multimode_lacp

Answer: B

 

NEW QUESTION 73
A Cisco UCS chasis has two power suppliers connected to one PDU and two power supplies connected to another PDU. You would like to protect against the failure of one entire PDU.
In this scenario, which power policy should you configure in UCS Manager?

  • A. grid
  • B. redundant
  • C. N+1
  • D. N+2

Answer: A

 

NEW QUESTION 74
Exhibit:

You just finished cabling a UCS 5108 chassis to the Fabric Interconnects.
Which diagram in the exhibit is cabled correctly according to the CVD guidelines?

  • A. IV
  • B. II
  • C. III
  • D. I

Answer: A

 

NEW QUESTION 75
You are asked to configure the computer resources in a FlexPod solution to ensure that jumbo frames are configured end-to-end.
Which three actions must you perform to accomplish this task? (Choose three.)

  • A. Enable jumbo frames on the operating system adapter.
  • B. Set the MTU size to 1500 on the vNIC template
  • C. Configure a UCS QoS System Class with the jumbo frames.
  • D. Enable jumbo frames on all of the switches between the initiator and the iSCI target.
  • E. Configure jumbo frames on the switch VLANs.

Answer: A,C,D

 

NEW QUESTION 76
Which two database types are supported with the VMWare vCenter 6.0 Server Appliance? (Choose two.)

  • A. vPostgres (embedded)
  • B. Microsoft SQL Server Express
  • C. Oracle
  • D. Microsoft SQL Server Enterprise

Answer: A,C

 

NEW QUESTION 77
Which server role is required to support running virtual machines on a Microsoft based hypervisor?

  • A. Web Server
  • B. Hyper-V
  • C. Application Server
  • D. Remote Access

Answer: B

 

NEW QUESTION 78
Refer to the exhibit.

What management tool may be used for creating virtual machines?

  • A. Hyper-V Manager
  • B. System Center Virtual Machine Manager
  • C. MMC
  • D. System Center Orchestrator

Answer: A

 

NEW QUESTION 79
Which statement is true about NFS exports in Clustered Data ONTAP?

  • A. Exports can be either persistent or temporary, and export policies and rules need to be set at the data Vserver level.
  • B. Export policies and rules need to be set at the data Vserver level.
  • C. Exports can be either persistent or temporary.
  • D. Export policies and rules need to be set at the data Vserver level and export policies are created and modified by editing /etc/exports on the node with the share.
  • E. Export policies are created and modified by editing /etc/exports on the node with the share.

Answer: B

 

NEW QUESTION 80
Refer to the exhibit.

Which is correct for configuring FCoE?

  • A. vlan 33fcoe vsan 43int po21switchport trunk allowed vsan add 43int vfc11bind interface po21vsan databasevsan 43 interface vfc 11
  • B. vlan 33fcoe vsan 43int po11switchport trunk allowed vlan add 33int vfc11bind interface po11switchport trunk allowed vsan 43vsan databasevsan 43 interface vfc11
  • C. fcoe vsan 43int po11switchport trunk allowed vsan add 43vsan databasevsan 43
  • D. fcoe vlan 33int po11switchport trunk allowed vlan add 33vsan databasevsan 33
  • E. fcoe vsan 43int po21switchport trunk allowed vsan add 43vsan databasevsan 43

Answer: B

 

NEW QUESTION 81
Exhibit:

Which hardware component is shown in the exhibit?

  • A. Fl
  • B. VIC
  • C. GEM
  • D. IOM

Answer: D

 

NEW QUESTION 82
You run NetApp ConfigAdvisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect.
Which set of commands will correct this problem?

  • A. network interface modify- node netapp-01 -port e0a -flowcontrol -admin none network interface modify -node netapp-02 -port e0a -flowcontrol - admin none
  • B. network port modify- node netapp-01 port e0a-flowcontrol-admin full network port modify- node netapp-02 port e0a-flowcontrol-admin full
  • C. network interface modify- node netapp-01 port e0a-flowcontrol-admin full network interface modify- node netapp-02 port e0a-flowcontrol-admin full
  • D. network port modify -node netapp-01 -port e0a -flowcontrol-admin none network port modify -node netapp-02 -port e0a -flowcontrol-admin none

Answer: D

 

NEW QUESTION 83
You have a FlexPod solution with Cisco 6296UP Fabric Interconnects. You currently have a direct-attached AFF8040 system using FCoE for storage connectivity. You would like to reconfigure the FlexPod so that the storage is connected through the upstream switches.
Using UCS Manager, which two steps would you perform to accomplish this task? (Choose two.)

  • A. Using the Configure Unified Ports wizard, change the port types to FC.
  • B. Configure the FI ports with the FCoE Uplink role.
  • C. Using the Configure Unified Ports wizard, change the port types to Ethernet.
  • D. Configure the FI ports with the Uplink role.

Answer: A,D

 

NEW QUESTION 84
Exhibit:

You have a FlexPod solution with vSphere ESXi. When you click the icons shown in the exhibit, you do not see any network connectivity details.
Which Cisco UCS policy type should you create to enable visibility of these details?

  • A. LAN Connectivity Policy
  • B. Link Profile Policy
  • C. Link Protocol Policy
  • D. Network Control Policy

Answer: A

 

NEW QUESTION 85
Your primary VSM needs to be edited, rebooted, or migrated. You need to initiate a manual switchover to your standby VSM.
What command will allow this to occur?

  • A. System switchover
  • B. Standby activate
  • C. System standby
  • D. vsm switchover

Answer: A

 

NEW QUESTION 86
Exhibit:

Your vSphere host is booting off an SD and is displaying the error shown in the exhibit.
What should you do to correct the problem?

  • A. Enable SD card mirroring.
  • B. Update the current ESXi scratch location.
  • C. Enable Unified Extensible Firmware Interface (UEFI).
  • D. Reinstall ESXi on a larger SD card.

Answer: B

 

NEW QUESTION 87
......

A fully updated 2022 NS0-176 Exam Dumps exam guide from training expert TrainingQuiz: https://www.trainingquiz.com/NS0-176-practice-quiz.html